Standard version, one measuring channel:
- n° 1 electro-pneumatic cabinet
( dimensions 500x500mm, h=266mm)
|
ELFER LT-5000 |
Differential pressure decay leak measurement.
Resolution: 1 Pa
Clean and dry air required.
Possibility to regulate test pressure:
Positive pressure from 0 to 6 bar
Negative pressure from 0 to 0.7 bar
Possibility to set up:
- Filling time;
- Stabilizing time;
- Testing time;
- Good/reject treshold;
Supply: 110/220 Vac, 24Vdc
|